Hanks HM2 Hydra™, Multiple Emitter, Multiple Crucible, Static e-Gun™

Evaporation Source
Series: Hanks

The Hydra™ Static series provides complex co-deposition process and co-evaporation of four or more different materials by efficient utilization of space. The unique modular magnetic design produces a more efficient electron beam. The Hyper-Unimelt 200 Hz sweep eliminates tunneling and source material eruptions. Plug-in emitter assemblies and sweep coil assemblies make the sources easier to service.

Hanks HM2 Hydra™, Multiple Emitter, Multiple Crucible, Static e-Gun™

The Hydra™ Static series provides complex co-deposition process and co-evaporation of four or more different materials by efficient utilization of space. The unique modular magnetic design produces a more efficient electron beam. The Hyper-Unimelt 200 Hz sweep eliminates tunneling and source material eruptions. Plug-in emitter assemblies and sweep coil assemblies make the sources easier to service.

Easy filament alignment, more efficient electron collimation, minimal filament distortion and elimination of electron trials. Perfect for co-evaporation!

Patents: 4,835,789; 4,891,291; 4,947,404

· Operate six (6) different materials simultaneously (additional crucible designs available upon request)

· All metal-sealed, fully UHV compatible, measured base pressure: 2×10-11 Torr.

· Hydra™ eliminates adjacent source interaction

· Patented magnetic design allows close source proximity for uniform coating and material interaction

· Each crucible source is independently water cooled to prevent steam buildup

· Each source crucible has separate sweep coils, insuring the independent operation integrity of each source, eliminating cross talk inference from adjacent sources

· Removable crucible chimney design for easy cleaning of deposition buildup

· H2O cooled emitter baseplate and crucible

· Available in 10kW or 15kW

· Crucible volume sizes: 10cc, 15cc, 40cc, (custom sizes available by request)

· 270° beam deflection, filament enclosure isolates any particulate exposure

· Dynamic crucible design available

· Easy emitter assembly removal design

· Thermionics’ Hyper-Unimelt Sweep design (optimum control on low or high rates)

· Horizontal and vertical source flange mount designs available

• Elimination of beam curl

• UHV rated sweep coils included with source (200 Hz)

• Elimination of pole pieces

• Easy filament alignment

• More efficient electron collimation

• Minimal filament distortion

• Elimination of electron tails

• Fully enclosed emitter assembly prevents particulate

buildup

• Each source is independent water cooled

• Designed to eliminate cross talk interference

Additional information

Crucible Volume

10cc, 15cc, 40cc